Audemars Piguet Museum 'Maison des Fondateurs'
Facade Consulting
All load-bearing curved insulating glass panels and glass supports at the "ADM" museum were inspected and thoroughly tested by the facade contractor at the manufacturer’s facility to ensure their quality and compliance with all specifications. The primary focus was on the structurally effective components of the insulating glass panels, as well as compliance with project-specific installation guidelines, the adhesive bonds, and the steel mounting brackets. This required continuous quality monitoring of all insulating glass elements. These had dimensions of up to 5200 mm x 2300 mm and had to meet specific product characteristics and requirements.